Part Number: 214-0006-009 | Manufacturer: Rockwell Collins Inc | NSN: 5925-01-050-9030 (5925010509030) | |
Item Name: circuit breaker | CAGE Code: 95105 | ||
Alternate P/N : 2140006009 |
Please utilize the RFQ form below to submit an online quote request for NSN part number 214-0006-009 of Circuit Breaker by manufacturer Rockwell Collins Inc having CAGE Code 95105 with NSN number 5925-01-050-9030. Please also fill the requested quantity and need by date form fields for your required part 214-0006-009. This information will help us prioritize your request effectively.
“*” Symbols for mandatory fields
Aerospace Orbit is owned and operated by ASAP Semiconductor – an AS9120B, ISO 9001:2015, and FAA AC 00-56B distributor of Rockwell Collins Inc NSN parts. We stock difficult-to-find parts from more than 75,000 manufacturers. Request a quote for part number 214-0006-009 and an account manager will contact you shortly.
Our industry relationships allow us to assure competitive prices on all obsolete parts, and shorten the supply chain to deliver as soon as possible. You will receive a response within 15 minutes from a sales representative at Aerospace Orbit. Additionally, you can call us at +1-714-705-4780 or submit a Bill of Materials (BOM) to sales@aerospaceorbit.com to expedite the purchase process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-050-9030 Item Description: Circuit Breaker | 5925 | 010509030 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
214-0006-009 | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
TTQY | Terminal Type And Quantity | 3 COMPRESSION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 10000.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
AJEC | Boss Height | 0.250 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
MRC | Decoded Requirement | Clear Text Reply |
AXHR | Mounting Facility Type And Quantity | 6 TERMINAL |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 2.230 INCHES NOMINAL |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | PLASTIC |
TTQY | Terminal Type And Quantity | 3 CLIP AND |
ADAQ | Body Length | 6.250 INCHES NOMINAL |
ADAU | Body Height | 2.580 INCHES NOMINAL |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 240.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT POLE TWO |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT |
Please Remember to Visit Us Again the Next Time You Need Parts.