Part Number: T4566 | Manufacturer: Opt Industries Inc | NSN: 5950-01-309-4081 (5950013094081) | |
Item Name: transformer power | CAGE Code: 53342 |
Please utilize the RFQ form below to submit an online quote request for NSN part number T4566 of Transformer Power by manufacturer Opt Industries Inc having CAGE Code 53342 with NSN number 5950-01-309-4081. Please also fill the requested quantity and need by date form fields for your required part T4566. This information will help us prioritize your request effectively.
“*” Symbols for mandatory fields
Aerospace Orbit is owned and operated by ASAP Semiconductor – an AS9120B, ISO 9001:2015, and FAA AC 00-56B distributor of Opt Industries Inc NSN parts. We stock difficult-to-find parts from more than 75,000 manufacturers. Request a quote for part number T4566 and an account manager will contact you shortly.
Our industry relationships allow us to assure competitive prices on all obsolete parts, and shorten the supply chain to deliver as soon as possible. You will receive a response within 15 minutes from a sales representative at Aerospace Orbit. Additionally, you can call us at +1-714-705-4780 or submit a Bill of Materials (BOM) to sales@aerospaceorbit.com to expedite the purchase process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-309-4081 Item Description: Transformer Power | 5950 | 013094081 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
T4566 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.945 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.955 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.945 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.955 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 67.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.230 INCHES MINIMUM AND 2.270 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.445 INCHES MINIMUM AND 1.455 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.3 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 4.5 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 20.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 37.58 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | TERMINALS 3 AND 3A ARE CONNECTED; TERMINALS 5 AND 5A ARE CONNECTED; TERMINALS 6 AND 6A ARE CONNECTED; TERMINALS 8 AND 8A ARE CONNECTED |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TEST | TEST DATA DOCUMENT | 04939-717601563 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DR |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAT | BODY WIDTH | 2.230 INCHES MINIMUM AND 2.270 INCHES MAXIMUM |
CWJS | WINDING OPERATING VOLTAGE | 23.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 12 PIN |