Please submit your quote request for NSN part 102744 (Transformer Power) using the RFQ form below. This part 102744 is manufactured by Dytek Laboratories (54519) and carries NSN 5950-00-276-5448. To expedite processing, kindly provide the requested quantity and need-by date in the designated form fields.
For reference, this part 102744 has an NSN of 5950-00-276-5448, with a NIIN of 00-276-5448 and an NCB Code of 00 (USA). It falls under FSG 59 Electrical and Electronic Equipment Components and FSC 5950 Coils and Transformers for classification purposes. Providing complete details ensures we prioritize your request effectively.
Note : We Will Not Share Your Information To Any Third Parties.
Aerospace Orbit, an ASAP Semiconductor company, is an AS9120B, ISO 9001:2015, and FAA AC 00-56B certified distributor specializing in Dytek Laboratories NSN parts. With access to over 75,000 manufacturers, we source even the most hard-to-find components.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-276-5448 Item Description: Transformer Power | 5950 | 002765448 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
102744 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.375 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.375 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.125 INCHES MINIMUM SINGLE GROUP AND 0.125 INCHES MINIMUM SINGLE GROUP AND 0.187 INCHES MAXIMUM SINGLE GROUP0.187 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA AND DELTA-DELTA AND DELTA-WYEDELTA-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.000 INCHES MAXIMUM3.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.750 INCHES MAXIMUM2.750 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.875 INCHES MINIMUM AND 3.875 INCHES MINIMUM AND 4.125 INCHES MAXIMUM4.125 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS170.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUPSLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 11 SECONDARY SINGLE COMPONENT11 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 17.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY17.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 17.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY17.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 17.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY17.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 17.50 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY17.50 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 180.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 180.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; ELEVEN SECONDARY WINDINGS,NEUTRAL TAP ON FIRST THRU NINTH SECONDARIESONE PRIMARY WINDING; ELEVEN SECONDARY WINDINGS,NEUTRAL TAP ON FIRST THRU NINTH SECONDARIES |
TTQY | TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, PLUG AND 43 TAB, SOLDER LUG |
CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
---|---|
HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
PMIC | A - Item does not contain precious metal. |
AAC | Z |
---|---|
Classification Control | U |
MGMT_CTL | 9b----- |
Quantity per pack | 1 |
Repariability | |
Shelf Life | N/A |
SOS | Sms |
Unit of Measure | Ea |
ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
---|---|
ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
LTL: | W - Rating variable |
NMFC: | 063420 - Transformers, noi, or transformer par |
SHC: | 9 - Other or no special handling required (sh) |
TCC: | Z - No special type of cargo code applicable |
WCC: | 595 - Transformer, (machinery and parts),(less than 35 feet) |
Quotes within 15 minutes |
|
Competitive Prices |
|
Dedicated and Knowledgeable |
|
AOG Services 24/7 x 365 |
|
Same-day |
Please Remember to Visit Us Again the Next Time You Need Parts.
Request for Quote