Please submit your quote request for NSN part 6011920-002 (Circuit Breaker) using the RFQ form below. This part 6011920-002 is manufactured by Bae Systems Information And Electronic Systems Integration Inc Div Bae Systems (12436) and carries NSN 5925-01-384-1950. To expedite processing, kindly provide the requested quantity and need-by date in the designated form fields.
For reference, this part 6011920-002 has an NSN of 5925-01-384-1950, with a NIIN of 01-384-1950 and an NCB Code of 01 (USA). It falls under FSG 59 Electrical and Electronic Equipment Components and FSC 5925 Circuit Breakers for classification purposes. Providing complete details ensures we prioritize your request effectively.
Note : We Will Not Share Your Information To Any Third Parties.
Aerospace Orbit, an ASAP Semiconductor company, is an AS9120B, ISO 9001:2015, and FAA AC 00-56B certified distributor specializing in Bae Systems Information And Electronic Systems Integration Inc Div Bae Systems NSN parts. With access to over 75,000 manufacturers, we source even the most hard-to-find components.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-384-1950 Item Description: Circuit Breaker | 5925 | 013841950 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
6011920-002 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ADTV | CASE MATERIAL | PLASTIC |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.062 INCHES NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC ALL LOCATIONS |
ADAT | BODY WIDTH | 1.500 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
AJEC | BOSS HEIGHT | 0.140 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 9.500 MINIMUM AT 200 PCT AND 150.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 4 THREADED STUD |
THSD | THREAD SERIES DESIGNATOR | UNC |
ADAQ | BODY LENGTH | 2.500 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.938 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.720 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 2 |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 265.0 AC ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | VIBRATION RESISTANT AND SHOCK RESISTANT AND MOISTURE RESISTANT |
FREQ | FREQUENCY IN HERTZ | 47.0 ALL LOCATIONS OR 440.0 ALL LOCATIONS |
End Use : 20005 | Electric apparatus |
---|---|
Schedule B : 8536200040 (NAICS 335313) | Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi |
SITC : 77252 | Automatic circuit breakers for a voltage not exceeding 1, 000 volts |
CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
---|---|
HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
PMIC | A - Item does not contain precious metal. |
AAC | J |
---|---|
Classification Control | U |
MGMT_CTL | Sf9eh-n |
Quantity per pack | 1 |
Repariability | |
Shelf Life | N/A |
SOS | Sms |
Unit of Measure | Ea |
ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
---|---|
ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
LTL: | P - 77.5 |
NMFC: | 061300 - Circuit breaker/switch noi |
SHC: | 9 - Other or no special handling required (sh) |
TCC: | Z - No special type of cargo code applicable |
WCC: | 658 - Electrical appliances, small |
Quotes within 15 minutes |
|
Competitive Prices |
|
Dedicated and Knowledgeable |
|
AOG Services 24/7 x 365 |
|
Same-day |
Please Remember to Visit Us Again the Next Time You Need Parts.
Request for Quote