Please submit your quote request for NSN part 720-010-339 (Capacitor Fixed Ceramic Dielectr) using the RFQ form below. This part 720-010-339 is manufactured by Andrew Scicomm Inc (17903) and carries NSN 5910-01-108-8389. To expedite processing, kindly provide the requested quantity and need-by date in the designated form fields.
For reference, this part 720-010-339 has an NSN of 5910-01-108-8389, with a NIIN of 01-108-8389 and an NCB Code of 01 (USA). It falls under FSG 59 Electrical and Electronic Equipment Components and FSC 5910 Capacitors for classification purposes. Providing complete details ensures we prioritize your request effectively.
Note : We Will Not Share Your Information To Any Third Parties.
Aerospace Orbit, an ASAP Semiconductor company, is an AS9120B, ISO 9001:2015, and FAA AC 00-56B certified distributor specializing in Andrew Scicomm Inc NSN parts. With access to over 75,000 manufacturers, we source even the most hard-to-find components.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-01-108-8389 Item Description: Capacitor Fixed Ceramic Dielectr | 5910 | 011088389 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
720-010-339 | 1 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.100 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.100 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.100 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
CQBQ | CAPACITANCE VALUE PER SECTION | 3.300 MICROFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 150.0 DEG CELSIUS MAXIMUM |
CQLZ | III TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | 0.0 SINGLE SECTION |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 100.0 DC SINGLE SECTION |
CRHD | TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | -30.0/+30.0 SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -0.10/+0.10 PICOFARADS SINGLE SECTION |
CWJK | CASE MATERIAL | PLASTIC |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.1000 |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
End Use : 20005 | Electric apparatus |
---|---|
Schedule B : 8532290040 (NAICS 334416) | Fixed capacitors, nesoi |
SITC : 77867 | Fixed capacitors, n.E.S. |
ADPE | Represents items with no adp components |
---|---|
CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
PMIC | A - Item does not contain precious metal. |
AAC | Z |
---|---|
Classification Control | U |
MGMT_CTL | Q2200x- |
Quantity per pack | 1 |
Repariability | This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Shelf Life | N/A |
SOS | Sms |
Unit of Measure | Ea |
ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
---|---|
ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
LTL: | P - 77.5 |
NMFC: | 061400 - Condensers/parts noi/capacitors |
SHC: | 9 - Other or no special handling required (sh) |
TCC: | Z - No special type of cargo code applicable |
WCC: | 72D - Communications/electronics, other than sigint/ew or comsec repair parts and components |
Quotes within 15 minutes |
|
Competitive Prices |
|
Dedicated and Knowledgeable |
|
AOG Services 24/7 x 365 |
|
Same-day |
Please Remember to Visit Us Again the Next Time You Need Parts.
Request for Quote